NEVER mix different products together in the same bottle or pail. Always add product to water, and never add water to product. Use eye and hand protection during the use of this product.
Using a clean plastic bucket or pail, add 1 pound of this product to 3 gallons of fresh water. DO NOT mix product in steel , metal, aluminum, or similar containers. Mix the solution thoroughly with a wooden or plastic spoon. Not all the product will dissolve in the pail. With the cell disconnected from its control box, submerge the plates in solution. Avoid submerging the disconnected power cord in the product solution. Allow cleaners to penetrate material in the cell plates for 15 to 30 minutes. Hardened materials on the cells may need some physical removal from the plates in the cell. Used diluted product is safe to dispose of into drains.